Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Artigo em Alemão | MEDLINE | ID: mdl-38190822

RESUMO

Acute respiratory distress syndrome (ARDS) is a common condition in intensive care medicine. Various intra- and extrapulmonal causes may trigger an epithelial and endothelial permeability increase, which leads to impaired gas exchange due to fluid overload of the alveoli and transmigration of leukocytes. This results in hypoxemia and hypercapnia, as well as deleterious consequences for the macro- and microcirculation with the risk of multi-organ failure and high mortality. This review summarizes ARDS pathophysiology and clinical consequences.


Assuntos
Síndrome do Desconforto Respiratório , Desequilíbrio Hidroeletrolítico , Humanos , Síndrome do Desconforto Respiratório/terapia , Cuidados Críticos , Insuficiência de Múltiplos Órgãos
2.
Membranes (Basel) ; 13(10)2023 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-37887981

RESUMO

Extracorporeal membrane oxygenation (ECMO) is an important rescue therapy method for the treatment of severe hypoxic lung injury. In some cases, oxygen saturation and oxygen partial pressure in the arterial blood are low despite ECMO therapy. There are case reports in which patients with such instances of refractory hypoxemia received a second membrane lung, either in series or in parallel, to overcome the hypoxemia. It remains unclear whether the parallel or serial connection is more effective. Therefore, we used an improved version of our full-flow ECMO mock circuit to test this. The measurements were performed under conditions in which the membrane lungs were unable to completely oxygenate the blood. As a result, only the photometric pre- and post-oxygenator saturations, blood flow and hemoglobin concentration were required for the calculation of oxygen transfer rates. The results showed that for a pre-oxygenator saturation of 45% and a total blood flow of 10 L/min, the serial connection of two identical 5 L rated oxygenators is 17% more effective in terms of oxygen transfer than the parallel connection. Although the idea of using a second membrane lung if refractory hypoxia occurs is intriguing from a physiological point of view, due to the invasiveness of the solution, further investigations are needed before this should be used in a wider clinical setting.

3.
ASAIO J ; 69(8): 789-794, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37146598

RESUMO

Interhospital transport of acute respiratory distress syndrome (ARDS) patients bears transport-associated risks. It is unknown how interhospital extracorporeal membrane oxygenation (ECMO) transfer of COVID-19 patients by mobile ECMO units affects ARDS mortality. We compared the outcome of 94 COVID-19 patients cannulated in primary care hospitals and retrieved by mobile ECMO-teams to that of 84 patients cannulated at five German ECMO centers. Patients were recruited from March 2020 to November 2021. Twenty-six transports were airborne, 68 were land-based. Age, sex, body-mass-index, Simplified Acute Physiology Score (SAPS) II, days invasively ventilated, and P/F-Ratio before ECMO initiation were similar in both groups. Counting only regional transports (≤250 km), mean transport distance was 139.5 km ± 17.7 km for helicopter (duration 52.5 ± 10.6 minutes) and 69.8 km ± 44.1 km for ambulance or mobile intensive care unit (duration 57.6 ± 29.4 minutes). Overall time of vvECMO support (20.4 ± 15.2 ECMO days for transported patients vs. 21.0 ± 20.5 for control, p = 0.83) and days invasively ventilated (27.9 ± 18.1 days vs. 32.6 ± 25.1 days, p = 0.16) were similar. Overall mortality did not differ between transported patients and controls (57/94 [61%] vs. 51/83 [61%], p = 0.43). COVID-19 patients cannulated and retrieved by mobile ECMO-teams have no excess risk compared with patients receiving vvECMO at experienced ECMO centers. Patients with COVID-19-associated ARDS, limited comorbidities, and no contraindication for ECMO should be referred early to local ECMO centers.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Pneumonia , Síndrome do Desconforto Respiratório , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , COVID-19/terapia , Ambulâncias , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia
4.
Artigo em Alemão | MEDLINE | ID: mdl-37192638

RESUMO

Veno-arterial extracorporeal life support (ECLS) may be indicated in patients with refractory heart failure. The list of conditions in which ECLS is successfully used is growing and includes cardiogenic shock following myocardial infarction, refractory cardiac arrest, septic shock with low cardiac output and severe intoxication. Femoral ECLS is the most common and often preferred ECLS-configuration in the emergency setting. Although femoral access is usually quick and easy to establish, it is also associated with specific adverse haemodynamic effects due to the direction of blood flow and access-site complications are inherent. Femoral ECLS provides adequate oxygen delivery and compensates for impaired cardiac output. However, retrograde blood flow into the aorta increases left ventricular afterload and may worsen left ventricular stroke work. Therefore, femoral ECLS is not equivalent to left ventricular unloading. Daily haemodynamic assessments are crucial and should include echocardiography and laboratory tests determining tissue oxygenation. Common complications include the harlequin-phenomenon, lower limb ischaemia or cerebral events and cannula site or intracranial bleeding. Despite a high incidence of complications and high mortality, ECLS is associated with survival benefits and better neurological outcomes in selected patient groups.


Assuntos
Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Função Ventricular Esquerda , Parada Cardíaca/complicações , Cuidados Críticos , Estudos Retrospectivos
5.
Notf Rett Med ; 26(3): 227-237, 2023.
Artigo em Alemão | MEDLINE | ID: mdl-37101845

RESUMO

Critically ill patients in need of specialized diagnostic or therapeutic procedures, but are being cared for in a hospital without such equipment, have to be transferred to appropriate centers without discontinuation of current critical care (interhospital critical care transfer). These transfers are resource intensive, challenging, and require high logistical effort, which must be managed by a specialized and highly trained team, predeployment planning and efficient crew-resource management strategies. If planned adequately, interhospital critical care transfers can be performed safely without frequent adverse events. Beside routine interhospital critical care transfers, there are special missions (e.g., for patients in quarantine or supported by extracorporeal organ support) that might require adaption of the team composition or standard equipment. This article describes interhospital critical care transport missions including their different phases and special circumstances.

6.
Anaesthesiologie ; 72(5): 317-324, 2023 05.
Artigo em Alemão | MEDLINE | ID: mdl-36930266

RESUMO

BACKGROUND: The SARS-CoV­2 pandemic posed unexpected challenges for hospitals worldwide and in addition to the supply emergency, simultaneously caused a high pressure to innovate. Due to the high number of cases of COVID-19 patients requiring intensive care, structured networking of hospitals gained particular importance. The tele-ICU communication platform TeleCOVID was developed to improve the quality of intensive care both by enabling teleconsultations and by supporting patient transfers. OBJECTIVE: The present study aimed to survey user experiences with TeleCOVID. The study investigated the extent to which the app is used, the user experiences of the participating hospitals, and the resulting implications for the further development of the telemedicine application. MATERIAL AND METHODS: A user survey was conducted in May 2022 using an online questionnaire. The survey contained both closed and open questions with a free text field. It was sent via the Hessian Ministry of Social Affairs and Integration (HMSI). All 135 hospitals in Hesse were contacted by e­mail and invited to participate in the study. The results of the closed questions were analyzed using descriptive statistics, and the results of the open questions were clustered and thematically summarized using qualitative content analysis. RESULTS: The study showed that TeleCOVID was used primarily for transfer requests, followed by the need for a treatment consultation without a transfer request. Most often, ECMO treatment or treatment in a hospital of a higher care level was required. The content analysis showed that users particularly rated the possibility of a data protection-compliant and structured transfer of patient data as advantageous. It is also worth mentioning that in almost 25% of the cases a transfer of patients could be prevented by TeleCOVID. Disadvantages frequently mentioned by respondents were the lack of connection to the electronic hospital information system, the increased time required for the registration process, and the poor primary accessibility of contact persons. CONCLUSION: In a further development of the application the connection to the electronic hospital information system should be considered particularly urgent. In addition, the time expenditure should be reduced by a simplified login process. Due to interface barriers, an alternative data infrastructure would also be conceivable to create interoperability. The introduction of a web client could also increase usability. The main beneficiaries of hospital networking are physicians and patients in a context associated with a high workload and specific medical issues. Continuation and expansion of the app to intensive care medicine and beyond are therefore recommended. In further studies on the project, personal interviews with decision makers could be useful to conduct a more targeted needs analysis.


Assuntos
COVID-19 , Cuidados Críticos , Consulta Remota , Humanos , Inquéritos e Questionários , Satisfação do Paciente , Telemedicina , Pandemias , Alemanha
7.
Perfusion ; 38(2): 245-260, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34550013

RESUMO

BACKGROUND: Adverse neurological events during extracorporeal membrane oxygenation (ECMO) are common and may be associated with devastating consequences. Close monitoring, early identification and prompt intervention can mitigate early and late neurological morbidity. Neuromonitoring and neurocognitive/neurodevelopmental follow-up are critically important to optimize outcomes in both adults and children. OBJECTIVE: To assess current practice of neuromonitoring during ECMO and neurocognitive/neurodevelopmental follow-up after ECMO across Europe and to inform the development of neuromonitoring and follow-up guidelines. METHODS: The EuroELSO Neurological Monitoring and Outcome Working Group conducted an electronic, web-based, multi-institutional, multinational survey in Europe. RESULTS: Of the 211 European ECMO centres (including non-ELSO centres) identified and approached in 23 countries, 133 (63%) responded. Of these, 43% reported routine neuromonitoring during ECMO for all patients, 35% indicated selective use, and 22% practiced bedside clinical examination alone. The reported neuromonitoring modalities were NIRS (n = 88, 66.2%), electroencephalography (n = 52, 39.1%), transcranial Doppler (n = 38, 28.5%) and brain injury biomarkers (n = 33, 24.8%). Paediatric centres (67%) reported using cranial ultrasound, though the frequency of monitoring varied widely. Before hospital discharge following ECMO, 50 (37.6%) reported routine neurological assessment and 22 (16.5%) routinely performed neuroimaging with more paediatric centres offering neurological assessment (65%) as compared to adult centres (20%). Only 15 (11.2%) had a structured longitudinal follow-up pathway (defined followup at regular intervals), while 99 (74.4%) had no follow-up programme. The majority (n = 96, 72.2%) agreed that there should be a longitudinal structured follow-up for ECMO survivors. CONCLUSIONS: This survey demonstrated significant variability in the use of different neuromonitoring modalities during and after ECMO. The perceived importance of neuromonitoring and follow-up was noted to be very high with agreement for a longitudinal structured follow-up programme, particularly in paediatric patients. Scientific society endorsed guidelines and minimum standards should be developed to inform local protocols.


Assuntos
Lesões Encefálicas , Oxigenação por Membrana Extracorpórea , Humanos , Adulto , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Europa (Continente)
8.
Med Klin Intensivmed Notfmed ; 118(6): 492-498, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-36074153

RESUMO

BACKGROUND: At the onset of the coronavirus pandemic, concerns were raised about sufficiency of available intensive care resources. In many places, routine interventions were postponed and criteria for the allocation of scarce resources were formulated. In Germany, some hospitals were at times seriously burdened during the course of the pandemic. Intensive care units in particular experienced a shortage of resources, which may have led to a restriction of services and a stricter indication setting for resource-intensive measures such as extracorporeal membrane oxygenation (ECMO). The aim of this work is to provide an overview of how these pressures were managed at large ECMO centers in Germany. METHODS: One representative of each major ECMO referral center in Germany was invited to participate in an online survey in spring 2021. RESULTS: Of 34 invitations that were sent out, the survey was answered by 23 participants. In all centers, routine procedures were postponed during the pandemic. Half of the centers increased the number of beds on which ECMO procedures could be offered. Nevertheless, in one-third of the centers, the start of at least one ECMO support was delayed because of a feared resource shortage. In 17% of centers, at least one patient was denied ECMO that he or she would have most likely received under prepandemic conditions. CONCLUSION: The results of this online survey indicate that the experienced pressures and resource constraints led some centers to be cautious about ECMO indications.


Assuntos
Oxigenação por Membrana Extracorpórea , Feminino , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Pandemias , Inquéritos e Questionários , Unidades de Terapia Intensiva , Alemanha
9.
Med Klin Intensivmed Notfmed ; 118(1): 73-83, 2023 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-36507960

RESUMO

Critically ill patients in need of specialized diagnostic or therapeutic procedures, but are being cared for in a hospital without such equipment, have to be transferred to appropriate centers without discontinuation of current critical care (interhospital critical care transfer). These transfers are resource intensive, challenging, and require high logistical effort, which must be managed by a specialized and highly trained team, predeployment planning and efficient crew-resource management strategies. If planned adequately, interhospital critical care transfers can be performed safely without frequent adverse events. Beside routine interhospital critical care transfers, there are special missions (e.g., for patients in quarantine or supported by extracorporeal organ support) that might require adaption of the team composition or standard equipment. This article describes interhospital critical care transport missions including their different phases and special circumstances.


Assuntos
Ambulâncias , Transferência de Pacientes , Humanos , Cuidados Críticos/métodos , Transporte de Pacientes/métodos , Estado Terminal/terapia
10.
J Clin Med ; 11(21)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36362465

RESUMO

Background: There is ongoing debate whether lung physiology of COVID-19-associated acute respiratory distress syndrome (ARDS) differs from ARDS of other origin. Objective: The aim of this study was to analyze and compare how critically ill patients with COVID-19 and Influenza A or B were ventilated in our tertiary care center with or without extracorporeal membrane oxygenation (ECMO). We ask if acute lung failure due to COVID-19 requires different intensive care management compared to conventional ARDS. Methods: 25 patients with COVID-19-associated ARDS were matched to a cohort of 25 Influenza patients treated in our center from 2011 to 2021. Subgroup analysis addressed whether patients on ECMO received different mechanical ventilation than patients without extracorporeal support. Results: Compared to Influenza-associated ARDS, COVID-19 patients had higher ventilatory system compliance (40.7 mL/mbar [31.8-46.7 mL/mbar] vs. 31.4 mL/mbar [13.7-42.8 mL/mbar], p = 0.198), higher ventilatory ratio (1.57 [1.31-1.84] vs. 0.91 [0.44-1.38], p = 0.006) and higher minute ventilation at the time of intubation (mean minute ventilation 10.7 L/min [7.2-12.2 L/min] for COVID-19 vs. 6.0 L/min [2.5-10.1 L/min] for Influenza, p = 0.013). There were no measurable differences in P/F ratio, positive end-expiratory pressure (PEEP) and driving pressures (ΔP). Respiratory system compliance deteriorated considerably in COVID-19 patients on ECMO during 2 weeks of mechanical ventilation (Crs, mean decrease over 2 weeks -23.87 mL/mbar ± 32.94 mL/mbar, p = 0.037) but not in ventilated Influenza patients on ECMO and less so in ventilated COVID-19 patients without ECMO. For COVID-19 patients, low driving pressures on ECMO were strongly correlated to a decline in compliance after 2 weeks (Pearson's R 0.80, p = 0.058). Overall mortality was insignificantly lower for COVID-19 patients compared to Influenza patients (40% vs. 48%, p = 0.31). Outcome was insignificantly worse for patients requiring veno-venous ECMO in both groups (50% mortality for COVID-19 on ECMO vs. 27% without ECMO, p = 0.30/56% vs. 34% mortality for Influenza A/B with and without ECMO, p = 0.31). Conclusion: The pathophysiology of early COVID-19-associated ARDS differs from Influenza-associated acute lung failure by sustained respiratory mechanics during the early phase of ventilation. We question whether intubated COVID-19 patients on ECMO benefit from extremely low driving pressures, as this appears to accelerate derecruitment and consecutive loss of ventilatory system compliance.

11.
J Clin Med ; 11(22)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36431292

RESUMO

Background: Extracorporeal hemadsorption eliminates proinflammatory mediators in critically ill patients with hyperinflammation. The use of a pumpless extracorporeal hemadsorption technique allows its early usage prior to organ failure and the need for an additional medical device. In our animal model, we investigated the feasibility of pumpless extracorporeal hemadsorption over a wide range of mean arterial pressures (MAP). Methods: An arteriovenous shunt between the femoral artery and femoral vein was established in eight pigs. The hemadsorption devices were inserted into the shunt circulation; four pigs received CytoSorb® and four Oxiris® hemadsorbers. Extracorporeal blood flow was measured in a range between mean arterial pressures of 45-85 mmHg. Mean arterial pressures were preset using intravenous infusions of noradrenaline, urapidil, or increased sedatives. Results: Extracorporeal blood flows remained well above the minimum flows recommended by the manufacturers throughout all MAP steps for both devices. Linear regression resulted in CytoSorb® blood flow [mL/min] = 4.226 × MAP [mmHg] - 3.496 (R-square 0.8133) and Oxiris® blood flow [mL/min] = 3.267 × MAP [mmHg] + 57.63 (R-square 0.8708), respectively. Conclusion: Arteriovenous pumpless extracorporeal hemadsorption resulted in sufficient blood flows through both the CytoSorb® and Oxiris® devices over a wide range of mean arterial blood pressures and is likely an intriguing therapeutic option in the early phase of septic shock or hyperinflammatory syndromes.

12.
ASAIO J ; 68(9): 1197-1203, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36066356

RESUMO

Low flow extracorporeal carbon dioxide removal (ECCO2R) is a promising approach to correct hypercapnic lung failure, facilitate lung protective ventilation in acute respiratory distress syndrome and to possibly prevent the application of invasive ventilation. However, the predominant availability of adult membrane lungs (MLs) at most intensive care units are burdens for low flow ECCO2R that intends to reduce cannula size and promote the mobility of the patients. Herein, in a mock setup, we combine the idea of a low flow ECCO2R and the use of adult MLs by installing a recirculation channel into the circuit and comparing the new setup to an already clinically established setup, "the Homburg lung." Furthermore, to make stronger reference to hypercapnic respiratory failure, we investigate the influence of CO2 partial pressure in blood on CO2 removal of both setups. A linear association between CO2 partial pressure in blood and CO2 removal of the ML in the physiologically relevant range was observed. To understand this linear dependence, a simplified mathematical model was proposed. Our new ECCO2R mock setup combines the idea of a low flow ECCO2R and an adult size ML. It shows a reasonable alternative to the current available low flow setups based on pediatric MLs.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Adulto , Dióxido de Carbono , Criança , Circulação Extracorpórea , Humanos , Hipercapnia , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia
14.
Membranes (Basel) ; 12(5)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35629818

RESUMO

Extracorporeal membrane oxygenation (ECMO) has become an important therapeutic approach in the COVID-19 pandemic. The development and research in this field strongly relies on animal models; however, efforts are being made to find alternatives. In this work, we present a new mock circuit for ECMO that allows measurements of the oxygen transfer rate of a membrane lung at full ECMO blood flow. The mock utilizes a large reservoir of heparinized porcine blood to measure the oxygen transfer rate of the membrane lung in a single passage. The oxygen transfer rate is calculated from blood flow, hemoglobin value, venous saturation, and post-membrane arterial oxygen pressure. Before the next measuring sequence, the blood is regenerated to a venous condition with a sweep gas of nitrogen and carbon dioxide. The presented mock was applied to investigate the effect of a recirculation loop on the oxygen transfer rate of an ECMO setup. The recirculation loop caused a significant increase in post-membrane arterial oxygen pressure (paO2). The effect was strongest for the highest recirculation flow. This was attributed to a smaller boundary layer on gas fibers due to the increased blood velocity. However, the increase in paO2 did not translate to significant increases in the oxygen transfer rate because of the minor significance of physically dissolved oxygen for gas transfer. In conclusion, our results regarding a new ECMO mock setup demonstrate that recirculation loops can improve ECMO performance, but not enough to be clinically relevant.

15.
ASAIO J ; 68(8): 1017-1023, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35617687

RESUMO

Coronavirus disease 2019 (COVID-19) has drastically increased the number of patients requiring extracorporeal life support. We investigate the efficacy and safety of low-dose recombinant tissue-type plasminogen activator (rtPA) injection into exhausted oxygenators to delay exchange in critically ill COVID-19 patients on veno-venous extracorporeal membrane oxygenation (V-V ECMO). Small doses of rtPA were injected directly into the draining section of a V-V ECMO circuit. We compared transmembrane pressure gradient, pump head efficiency, membrane arterial partial oxygen pressure, and membrane arterial partial carbon dioxide pressure before and after the procedure. Bleeding was compared with a matched control group of 20 COVID-19 patients on V-V ECMO receiving standard anticoagulation. Four patients received 16 oxygenator instillations with rtPA at 5, 10, or 20 mg per dose. Administration of rtPA significantly reduced transmembrane pressure gradient (Δ pm = 54.8 ± 18.1 mmHg before vs . 38.3 ± 13.3 mmHg after, p < 0.001) in a dose-dependent manner (Pearson's R -0.63, p = 0.023), allowing to delay oxygenator exchange, thus reducing the overall number of consumed oxygenators. rtPA increased blood flow efficiency η (1.20 ± 0.28 ml/revolution before vs . 1.24 ± 0.27 ml/r, p = 0.002). Lysis did not affect membrane blood gases or systemic coagulation. Minor bleeding occurred in 2 of 4 patients (50%) receiving oxygenator lysis as well as 19 of 20 control patients (95%). Lysis of ECMO oxygenators effectively delays oxygenator exchange, if exchange is indicated by an increase in transmembrane pressure gradient. Application of lysis did not result in higher bleeding incidences compared with anticoagulated patients on V-V ECMO for COVID-19.


Assuntos
Tratamento Farmacológico da COVID-19 , Oxigenação por Membrana Extracorpórea , Oxigenadores de Membrana , Ativador de Plasminogênio Tecidual , Gasometria , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Ativador de Plasminogênio Tecidual/uso terapêutico
16.
ASAIO J ; 68(8): 996-1001, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35412477

RESUMO

In late 2020, during the second wave of COVID-19 in Germany, we started using the MobyBox, which is a novel fully pneumatically driven ECMO device, on a regular basis to meet the increasing demand for ECMO therapy. In this case series, we performed a retrospective chart review of seven patients with severe COVID-19-related acute respiratory distress syndrome (ARDS) requiring veno-venous (vv)-ECMO support with the MobyBox. During ECMO treatments we have observed no disadvantages in comparison to conventional ECMO systems. There were no system failures or adverse events directly attributable to the MobyBox system. Our data support that providing vv-ECMO with the MobyBox device is safe and feasible. Furthermore, our findings suggest that the MobyBox device might represent an advantage in terms of biocompatibility. Therefore, more data on this issue is needed to better understand how the pneumatically driven pump affects cellular blood components.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , Estudos Retrospectivos
17.
Intensive Care Med ; 48(3): 332-342, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35146534

RESUMO

PURPOSE: The question of whether cancer patients with severe respiratory failure benefit from veno-venous extracorporeal membrane oxygenation (vv-ECMO) remains unanswered. We, therefore, analyzed clinical characteristics and outcomes of a large cohort of cancer patients treated with vv-ECMO with the aim to identify prognostic factors. METHODS: 297 cancer patients from 19 German and Austrian hospitals who underwent vv-ECMO between 2009 and 2019 were retrospectively analyzed. A multivariable cox proportional hazards analysis for overall survival was performed. In addition, a propensity score-matched analysis and a latent class analysis were conducted. RESULTS: Patients had a median age of 56 (IQR 44-65) years and 214 (72%) were males. 159 (54%) had a solid tumor and 138 (47%) a hematologic malignancy. The 60-day overall survival rate was 26.8% (95% CI 22.1-32.4%). Low platelet count (HR 0.997, 95% CI 0.996-0.999; p = 0.0001 per 1000 platelets/µl), elevated lactate levels (HR 1.048, 95% CI 1.012-1.084; p = 0.0077), and disease status (progressive disease [HR 1.871, 95% CI 1.081-3.238; p = 0.0253], newly diagnosed [HR 1.571, 95% CI 1.044-2.364; p = 0.0304]) were independent adverse prognostic factors for overall survival. A propensity score-matched analysis with patients who did not receive ECMO treatment showed no significant survival advantage for treatment with ECMO. CONCLUSION: The overall survival of cancer patients who require vv-ECMO is poor. This study shows that the value of vv-ECMO in cancer patients with respiratory failure is still unclear and further research is needed. The risk factors identified in the present analysis may help to better select patients who may benefit from vv-ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Neoplasias , Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Adulto , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Neoplasias/terapia , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Estudos Retrospectivos
19.
ERJ Open Res ; 7(2)2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34159186

RESUMO

This correspondence argues that data presented previously cannot justify a novel approach for treating hypoxic patients with severe #COVID19 https://bit.ly/3dLaPlk.

20.
Membranes (Basel) ; 11(6)2021 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-34072067

RESUMO

Extracorporeal carbon dioxide removal (ECCO2R) is an important technique to treat critical lung diseases such as exacerbated chronic obstructive pulmonary disease (COPD) and mild or moderate acute respiratory distress syndrome (ARDS). This study applies our previously presented ECCO2R mock circuit to compare the CO2 removal capacity of circular versus parallel-plated membrane lungs at different sweep gas flow rates (0.5, 2, 4, 6 L/min) and blood flow rates (0.3 L/min, 0.9 L/min). For both designs, two low-flow polypropylene membrane lungs (Medos Hilte 1000, Quadrox-i Neonatal) and two mid-flow polymethylpentene membrane lungs (Novalung Minilung, Quadrox-iD Pediatric) were compared. While the parallel-plated Quadrox-iD Pediatric achieved the overall highest CO2 removal rates under medium and high sweep gas flow rates, the two circular membrane lungs performed relatively better at the lowest gas flow rate of 0.5 L/min. The low-flow Hilite 1000, although overall better than the Quadrox i-Neonatal, had the most significant advantage at a gas flow of 0.5 L/min. Moreover, the circular Minilung, despite being significantly less efficient than the Quadrox-iD Pediatric at medium and high sweep gas flow rates, did not show a significantly worse CO2 removal rate at a gas flow of 0.5 L/min but rather a slight advantage. We suggest that circular membrane lungs have an advantage at low sweep gas flow rates due to reduced shunting as a result of their fiber orientation. Efficiency for such low gas flow scenarios might be relevant for possible future portable ECCO2R devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...